<p>The <b>zero-order hold</b> (<b>ZOH</b>) is a mathematical model of the practical <a href="page.php?w=signal_reconstruction">signal reconstruction</a> done by a conventional <a href="page.php?w=digital-to-analog_converter">digital-to-analog converter</a> (DAC).  That is, it describes the effect of converting a <a href="page.php?w=discrete-time_signal">discrete-time signal</a> to a <a href="page.php?w=continuous-time_signal">continuous-time signal</a> by holding each sample value for one sample interval. It has several applications in electrical</p><p>