<p>a particular application." This means that A326.3 should not be used to assess real-world slip risk, but is rather a useful test method to assess changes in slip resistance due to wear, maintenance practices, and other factors.</p>

<p><big> Variable-angle ramp </big></p>
<p>The Variable-Angle Ramp is a German-developed method for obtaining pedestrian slip resistance values. Flooring samples are mounted horizontally on the ramp tester and an operator clad in safety boots or bare feet performs a standardized walk up and down the sample while wearing a</p><p>