<p>said to have a pulse-number of three, since the output voltage on the DC side contains three distinct pulses per cycle of the grid frequency:</p>

<p>The peak values  of this three-pulse DC voltage are calculated from the RMS value  of the input phase voltage (line to neutral voltage, 120&nbsp;V in North America, 240&nbsp;V within Europe at mains operation): . The average no-load output voltage  results from the <a href="page.php?w=integral">integral</a> under the graph of a positive half-wave with the period duration of  (from 30° to 150°):<div style="overflow:auto;><br/>