<p>some mix of motor-driven, diesel-driven, and turbine-driven to ensure redundancy. A turbine-driven auxiliary feedwater pump is powered by steam generated by the decay heat removal from the secondary side steam circuit of the plant. The typical <a href="page.php?w=steam_turbine">steam turbine</a> used in the auxiliary feedwater systems are the "solid wheel" or "water wheel" Terry Steam Turbines manufactured by the <a href="page.php?w=Curtiss-Wright">Curtiss-Wright Corporation</a> in Summerville, SC.</p>

<p>In contrast to <a href="page.php?w=nuclear_reactor_safety_system">emergency core cooling systems</a></p><p>